DriSteem Vaporstream Especificações

Consulte online ou descarregue Especificações para Desumidificadores DriSteem Vaporstream. DriSteem Vaporstream Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Vaporstream

Vaporstream®Electric-to-SteamHumidification SystemPR0DUCT CATALOGNow with Vapor-logic®4 controller:• Web-enabled access• Interoperability via Modbu

Página 2 - DRI-STEEM® offers a

Page 10 • DRI-STEEM Vaporstream humidifierVaporstream dimensionsFigure 10-1:Vaporstream VLC dimensions, standard water and DI/RO waterVLC-OM-039Table

Página 3

DRI-STEEM Vaporstream humidifier • Page 11Vaporstream control cabinetsControl cabinet features The standard Vaporstream control cabinet is an ETL- and

Página 4 - Vapor-logic4 controller

Page 12 • DRI-STEEM Vaporstream humidifierVaporstream mountingFigure 12-1: Trapeze hangerVLC-OM-005CleanoutProvide 18" (457 mm) minimum clearance

Página 5 - Figure 5-1:

DRI-STEEM Vaporstream humidifier • Page 13Vaporstream mountingVLC-OM-006Optional set of four legs and hardwareFigure 13-2: Support legs DRI-STEEM opt

Página 6 - Vaporstream components

Page 14 • DRI-STEEM Vaporstream humidifierVaporstream VLC piping: Standard waterFigure 14-1:Field piping overview, Vaporstream VLC with standard water

Página 7

DRI-STEEM Vaporstream humidifier • Page 15Figure 15-1:Field piping overview, Vaporstream VLC with DI/RO waterNotes:• Locate air gap only in spaces wi

Página 8 - Table 8-1:

Page 16 • DRI-STEEM Vaporstream humidifierVaporstream outdoor enclosure overviewFigure 16-1:Outdoor enclosureOutdoor humidifier operation in any clima

Página 9 - Vaporstream weights and

DRI-STEEM Vaporstream humidifier • Page 17Vaporstream outdoor enclosureFigure 17-1:Typical rooftop installation overviewFigure 17-2:Outdoor enclosure

Página 10 - Vaporstream dimensions

Page 18 • DRI-STEEM Vaporstream humidifierVaporstream outdoor enclosureTable 18-1:Vaporstream outdoor enclosure dimensions*Item DescriptionVaporstream

Página 11 - Vaporstream control cabinets

DRI-STEEM Vaporstream humidifier • Page 19Vaporstream outdoor enclosureFigure 19-1:Vaporstream outdoor enclosure, top viewBStandard steam outlet (exit

Página 12 - Vaporstream mounting

Page 2 • DRI-STEEM Vaporstream humidifierApplication versatilityFrom providing comfort humidity to meeting the strictest clean-room requirements, the

Página 13

Page 20 • DRI-STEEM Vaporstream humidifiermc_022310_1645mc_020110_1255Vaporstream weather coverThe optional Vaporstream weather cover is water-resista

Página 14 - Standard water

DRI-STEEM Vaporstream humidifier • Page 21Guaranteed non-wetting distancesUsing data collected in our on-site test lab, we have developed guaranteed s

Página 15 - DI/RO water

Page 22 • DRI-STEEM Vaporstream humidifierUltra-sorb®• Double-header design• Shortest non-wetting distance; install within inches of upstream dampers

Página 16

DRI-STEEM Vaporstream humidifier • Page 23Vaporstream steam dispersion optionsFigure 23-2: Area-type dispersion VLC-OM-17Space Distribution Units (SDU

Página 17 - Vaporstream outdoor enclosure

Page 24 • DRI-STEEM Vaporstream humidifierCalculating non-wetting distancesSample exerciseRead through this exercise to learn more about specifying a

Página 18

DRI-STEEM Vaporstream humidifier • Page 25Ultra-sorb dispersionNote: The above data apply to all air velocities up to 1,500 fpm (7.6 m/s), and are bas

Página 19

Page 26 • DRI-STEEM Vaporstream humidifierUltra-sorb dimensionsmc_050808_1215Ultra-sorb LV • Vertical dispersion tubes• Suitable for AHUs or ductwor

Página 20 - Vaporstream weather cover

DRI-STEEM Vaporstream humidifier • Page 27mc_042710_1410Note: The above data apply to all air velocities up to 1,500 fpm (7.6 m/s) and are based on ai

Página 21 - Drip-free dispersion basics

Page 28 • DRI-STEEM Vaporstream humidifiermc_042710_1415Figure 28-1: Rapid-sorb dimensions1½" (DN40) dia. dispersion tubesuse slip couplingCEscut

Página 22

DRI-STEEM Vaporstream humidifier • Page 29Single tube with condensate drain:Recommended pitch toward humidifier for interconnecting hose, tubing or pip

Página 23 - Figure 23-1:

DRI-STEEM Vaporstream humidifier • Page 3Vaporstream features and benefitsProven performance• Consistent and reliable RH control to ±1%• On-off or t

Página 24 - DRI-STEEM Design

Page 30 • DRI-STEEM Vaporstream humidifierSDU-E and SDU-I dispersionTable 30-2: Space Distribution Unit specifications**SDU modelMaximum capacityShip

Página 25 - Ultra-sorb dispersion

DRI-STEEM Vaporstream humidifier • Page 31mc_030210_0940Area-type dispersionFigure 31-1: Area-type rise, spread, throwVLC-OM-020Table 31-2:Area-type e

Página 26 - Ultra-sorb dimensions

mc_022310_1415DRI-STEEM CorporationAn ISO 9001:2000 certified companyU.S. Headquarters:14949 Technology DriveEden Prairie, MN 55344800-328-4447 or 952

Página 27 - Rapid-sorb dispersion

Page 4 • DRI-STEEM Vaporstream humidifierVapor-logic4 controllerAccurate, responsive controlThe Vapor-logic4 controller provides accurate, responsive

Página 28 - Rapid-sorb dimensions

DRI-STEEM Vaporstream humidifier • Page 5Vaporstream principle of operation1. When the system is first activated, the fill valve opens and the evapor

Página 29 - Single tube dispersion

Page 6 • DRI-STEEM Vaporstream humidifierVaporstream componentsFigure 6-2:Vaporstream componentsVLC-OM-001X1. Vapor-logic4 controllerVapor-logic4 co

Página 30 - SDU-E and SDU-I dispersion

DRI-STEEM Vaporstream humidifier • Page 7Humidifiers using tap or softened water control water levels electronically using a three-rod probe. The cont

Página 31

Page 8 • DRI-STEEM Vaporstream humidifierVaporstream capacities and electrical specificationsTable 8-1:Vaporstream VLC capacities and electrical speci

Página 32 - Conserving resources

DRI-STEEM Vaporstream humidifier • Page 9Vaporstream weights and cabinet sizesTable 9-1:Vaporstream VLC weights and control cabinet sizes, standard wa

Comentários a estes Manuais